Annular centrifugal contactors (ACCs) have many advantages and are therefore favored for nuclear processes. Effects of various structure parameters including diameter of the heavy phase weir, length of the separating zone, width of annular gap, and the clearance height between the top of the vanes and the bottom of the rotor on the hydraulic performance of the ϕ20 ACC were investigated under 3500 r/min and 4500 r/min of rotor speed. The nominal total flow is increased with increase of length of the separating zone below 50 mm and diameter of the heavy phase weir below 12 mm. The effect of the annular gap width on the nominal total flow is complex. The effect of the different clearance height on the nominal total flow is unobvious. These results obtained will guide design and operation of the ϕ20 ACC and other types ACC.
Journal: Energy Procedia - Volume 39, 2013, Pages 461-466