Positive and Negative Effects on Energy Consumption by Inter–heating of Stripper in Co2 Capture Plant
چکیده انگلیسی

The effect of heat distribution or inter-heating on the total energy requirement for CO2 stripping is investigated. Here we look at retrofit design of an existing column. It means the height and diameter of the stripper is given. The results show that inter-heating can have both negative and positive effects on the total energy requirement. If only one heat source at constant temperature exist, the inter-heating will increase the total energy requirement. If there are other heat sources at different temperatures, inter-heating can be beneficial. It depends on the energy price of the different heat sources and the temperature profile of the column. If there are some hot streams available to utilize the heat in the inter-heater, the total energy requirement will decrease. As a case study utilizing heat from lean amine in the inter-heater is investigated. The simulation results show a saving up to 6.4 and 11.3 percent by one and two inter–heater respectively

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Procedia - Volume 23, 2012, Pages 15-22