Study on Opposite Experiment between Grid Fabric Filter and Orifice Plate Fabric Filter
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Study on Opposite Experiment between Grid Fabric Filter and Orifice Plate Fabric Filter
چکیده انگلیسی

The orifice plate of self-pressure fabric filter was improved on the basis of the virtue and defect of a variety of fabric filter. Various respects and better prospects of grid fabric filter were proofed on operational cycle, period water volume and backwashing characteristic while filtering at high flow-rate and large discharge. It is showed that at the same filter conditions: the initial filtering rate is 40 m/h, compared with orifice plate fabric filter (operational cycle is 40 h, period water volume is about 7.5 m3 and the removal rate of mud is 70% in 10 minutes), operational cycle is 50 h, period water volume is about 9.5 m3 and the removal rate of mud is 90% in 10 minutes when grid fabric filter is run. The larger the initial filtering rate is, the more obvious the contrast is. Period water volume of grid fabric filter is about 2 times than of orifice plate fabric filter when initial filtering rate is 60 m/h, so that grid fabric filter have better application prospect at large discharge industrial consumption.