چکیده انگلیسی


• Evaluating the migration of 210Po outside primary loop during normal operation.
• Activation calculations have been performed using the MCNP and FISPACT-2007 codes.
• The Raoult's Law was used to characterize the evaporation model of 210Po.
• The level of 210Po in the reactor building of China LEAd-based Research Reactor could not be harmful to workers.

An important issue should be considered for liquid lead–bismuth eutectic (LBE) cooled reactors, which is the accumulation of radioactive 210Po generated by neutron-irradiated LBE. It could cause problems during maintenance or refueling operations. Considering the safety of China LEAd-based Research Reactor (CLEAR-I), the activity of 210Po in LBE coolant was calculated by VisualBUS system developed by FDS Team. The evaporation process from LBE to cover gas and migration to containing room and reactor building during normal operations were evaluated in this present work. According to preliminary analysis, there is little 210Po contamination diffusing into the reactor building and its level in gaseous effluent was within the limits of NRC Regulation (10 CFR). It could not lead to problems during normal operations.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Nuclear Energy - Volume 70, January 2014, Pages 39–42
نویسندگان
, , , , ,