Thermal power calibrations of the IPR-R1 TRIGA reactor by the calorimetric and the heat balance methods
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Thermal power calibrations of the IPR-R1 TRIGA reactor by the calorimetric and the heat balance methods
چکیده انگلیسی

Since the first nuclear reactor was built, a number of methodological variations have been evolved for the calibration of the reactor thermal power. Power monitoring of reactors is done by means of neutronic instruments, but its calibration is always done by thermal procedures. The purpose of this paper is to present the results of the thermal power calibration carried out on March 5th, 2009 in the IPR-R TRIGA reactor. It was used two procedures: the calorimetric and heat balance methods. The calorimetric procedure was done with the reactor operating at a constant power, with primary cooling system switched off. The rate of temperature rise of the water was recorded. The reactor power is calculated as a function of the temperature-rise rate and the system heat capacity constant. The heat balance procedure consists in the steady-state energy balance of the primary cooling loop of the reactor. For this balance, the inlet and outlet temperatures and the water flow in the primary cooling loop were measured. The heat transferred through the primary loop was added to the heat leakage from the reactor pool. The calorimetric method calibration presented a large uncertainty. The main source of error was the determination of the heat content of the system, due to a large uncertainty in the volume of the water in the system and a lack of homogenization of the water temperature. The heat balance calibration in the primary loop is the standard procedure for calibrating the power of the IPR-R1 TRIGA nuclear reactor.


► Methodological variations have been used for TRIGA reactor thermal power calibration.
► Power monitoring of reactors is done by means of neutronic instruments.
► It was used two procedures: the calorimetric and heat balance methods.
► The calorimetric method calibration presented a large uncertainty.
► The heat balance is the standard procedure for IPR-R1 reactor power calibrating.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Nuclear Energy - Volume 53, Issue 8, November 2011, Pages 1197–1203
نویسندگان
, , ,