کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1741372 1017387 2009 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
DIAL–phoswich hybrid system for remote sensing of radioactive plumes in order to evaluate external dose rate
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
DIAL–phoswich hybrid system for remote sensing of radioactive plumes in order to evaluate external dose rate
چکیده انگلیسی

Radioactive pollutants which are released into the atmosphere are known to present a hazard to human health; therefore they must be identified and well protected. Here, an improved remote sensing system is investigated for monitoring radioactive plumes released into the atmosphere from nuclear sites. It is based on the combination of DIAL technique with a phoswich detector array. The DIAL, using a tunable UV/Vis laser, measures the concentration of the radionuclide and the plume distance, whereas the phoswich detects characteristic hard X/γ ray emissions. Here, we have shown the ability of a hybrid system for the prompt identification and quantification of the effluents containing the uranium radionuclide, using the parameters of uranium such as absorption cross-section, absorption spectrum and density.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Nuclear Energy - Volume 51, Issue 3, April 2009, Pages 420–433
نویسندگان
, ,