کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1741397 | 1017388 | 2011 | 6 صفحه PDF | دانلود رایگان |

In the present work the validity of applying the Boussinesq approximation in the analysis of natural convection heat transfer along nuclear fuel plates with large coolant channel aspect ratios is evaluated. The Boussinesq approximation is introduced into the integral boundary layer equations governing the system to describe the velocity and temperature distributions of the coolant in the cooling channels. The fuel plate temperature is related to the adjacent coolant fluid temperature by a fundamental law in conduction heat transfer. Air and water are considered as fluids. The coolant flow is assumed to be fully developed which is a convenient assumption for coolant channels having large aspect ratios. Obtained results indicate that the Boussinesq approximation is merely applicable over a limited range of coolant channel outlet fluid temperatures. The use of this approximation produces conservative estimation of the critical plate power for air flow and non-conservative estimation of the critical plate power for water flow.
Journal: Progress in Nuclear Energy - Volume 53, Issue 2, March 2011, Pages 223–228