Analysis of the VVER1000 coolant trip benchmark using the coupled RELAP5/PARCS code
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Analysis of the VVER1000 coolant trip benchmark using the coupled RELAP5/PARCS code
چکیده انگلیسی

Incorporation of full three-dimensional models of the reactor core into system thermal–hydraulic transient codes allows better estimation of interactions between the core behavior and plant dynamics. Considerable efforts have been made in various countries and organizations to verify and validate the capability of the so-called coupled codes technique. For these purposes appropriate Light Water Reactor (LWR) transient benchmarks based upon programmed transients performed in Nuclear Power Plants (NPP) were recently developed on a higher ‘best-estimate’ level. The reference problem considered in the current framework is a Main Coolant Pump (MCP) switching-on transient in a VVER1000 NPP. This event is characterized by a positive reactivity addition as consequence of the increase of the core flow. In the current study the coupled RELAP5/PARCS code is used to reproduce the considered test. Results of calculation were assessed against experimental data and also through the code-to-code comparison.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Progress in Nuclear Energy - Volume 48, Issue 8, November 2006, Pages 806–819
نویسندگان
, , , , ,