کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1759081 1019263 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Pulse compression technique for simultaneous HIFU surgery and ultrasonic imaging: A preliminary study
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
پیش نمایش صفحه اول مقاله
Pulse compression technique for simultaneous HIFU surgery and ultrasonic imaging: A preliminary study
چکیده انگلیسی

In an ultrasound image-guided High Intensity Focused Ultrasound (HIFU) surgery, reflected HIFU waves received by an imaging transducer should be suppressed for real-time simultaneous imaging and therapy. In this paper, we investigate the feasibility of pulse compression scheme combined with notch filtering in order to minimize these HIFU interference signals. A chirp signal modulated by the Dolph–Chebyshev window with 3–9 MHz frequency sweep range is used for B-mode imaging and 4 MHz continuous wave is used for HIFU. The second order infinite impulse response notch filters are employed to suppress reflected HIFU waves whose center frequencies are 4 MHz and 8 MHz. The prototype integrated HIFU/imaging transducer that composed of three rectangular elements with a spherically con-focused aperture was fabricated. The center element has the ability to transmit and receive 6 MHz imaging signals and two outer elements are only used for transmitting 4 MHz continuous HIFU wave. When the chirp signal and 4 MHz HIFU wave are simultaneously transmitted to the target, the reflected chirp signals mixed with 4 MHz and 8 MHz HIFU waves are detected by the imaging transducer. After the application of notch filtering with pulse compression process, HIFU interference waves in this mixed signal are significantly reduced while maintaining original imaging signal. In the single scanline test using a strong reflector, the amplitude of the reflected HIFU wave is reduced to −45 dB. In vitro test, with a sliced porcine muscle shows that the speckle pattern of the restored B-mode image is close to that of the original image. These preliminary results demonstrate the potential for the pulse compression scheme with notch filtering to achieve real-time ultrasound image-guided HIFU surgery.


► A method for simultaneous HIFU therapy and imaging was investigated.
► The combination of chirp signal and notch filtering could reduce HIFU noise in B-mode image.
► A prototype integrated HIFU/imaging transducer was fabricated and an in vitro test was conducted.
► The image quality of the restored B-mode image could be maintained compared to the pre-HIFU image.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasonics - Volume 52, Issue 6, August 2012, Pages 730–739
نویسندگان
, , ,