کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1872262 1530997 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Observation of the thermosiphon effect in the circulation of liquid nitrogen in HTS cable cooling system
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک و نجوم (عمومی)
پیش نمایش صفحه اول مقاله
Observation of the thermosiphon effect in the circulation of liquid nitrogen in HTS cable cooling system
چکیده انگلیسی

It is traditionally considered that superconducting technology is just the way that will help to overcome the energy crisis and improve the environmental safety of the electricity production. However, real achievements in this field still insufficient to build commercial long power transmission lines. In particular, cooling systems constructed using expensive coolant circulation pumps have to be improved. Our previous calculations show that the use of a thermosiphon effect may reduce both the heat load and the required coolant circulation pump power and, ideally, would completely abandon the forced circulation. Direct experimental verification of this approach has been carried out at the new 200-meter HTS DC experimental facility of the Chubu University. The thermosiphon effect was clearly observed in satisfactory agreement with theory, although the change in elevation of the cryopipe was small. Our results will be used to design an effective HTS cable cooling system based on natural circulation of the coolant.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physics Procedia - Volume 27, 2012, Pages 368-371