کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1880576 1533419 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Construction and calibration of a multipurpose instrument to simultaneously measure dose, voltage and half-value layer in X-ray emission equipment
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Construction and calibration of a multipurpose instrument to simultaneously measure dose, voltage and half-value layer in X-ray emission equipment
چکیده انگلیسی


• Construction and calibration of a novel instrument to measure dose, kVp and HVL.
• Materials displaying appropriate characteristics improve kVp estimates.
• The multipurpose instrument may help quality control of X-ray equipment.

This work reports on the development of a multipurpose instrument that simultaneously measures delivered dose (air kerma), peak voltage (kVp) and half value layer (HVL) in X-ray machines. The device will help control quality of X-ray equipment routinely used in diagnostic and interventional radiological procedures. The measuring device is equipped with several attenuating filters of different materials and thicknesses, and Gafchromic® XR-QA2 radiochromic films are used as sensitive elements. The films are scanned after being irradiated and the resulting color intensities indicate a relationship between the degree of film darkening under each individual filter and the quantities of interest, i.e. air kerma, kVp and HVL. Comparing HVL values measured using the proposed multipurpose instrument with those of a reference standard ionization chamber, discrepancy reached 8.4%. As for the kVp evaluation, anomalous results were observed for low atomic number materials and small thicknesses, especially for peak voltages higher than 70 kVp. However, for materials with higher Z and reasonable thickness, the calibration curve R × kVp was quite satisfactory, being R the ratio between the color intensities obtained with two distinct filters. We have also observed a decrease in the influence of Tungsten characteristic radiation on the calibration curve. These results suggest that the proposed instrument may be satisfactorily used to routinely control quality of X-ray equipment, estimating the radiation dose resulting from the direct beam, the applied voltage across the electrodes and the half value layer.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 71, December 2014, Pages 178–182
نویسندگان
, ,