کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1884405 1533401 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a protocol for small beam bi-dimensional dose distribution measurements with radiochromic films
ترجمه فارسی عنوان
توسعه یک پروتکل اندازه گیری توزیع دوزهای دو بعدی دوزبانه با فیلم های رادیو کروم
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی


• Uniformity of a flatbed scanner and radiochromic films were investigated.
• A “four films” dosimeter was designed to reduce experimental uncertainties.
• An accurate bi-dimensional dose measurement protocol was developed.
• Measurements were performed in stereotactic radiotherapy conditions.
• The protocol was validated with Monte Carlo simulations.

Gafchromic™ films have become popular due to their ease of use and their near water equivalence. This last property is crucial for stereotactic small beam dosimetry as demonstrated in recent papers. An accurate bi-dimensional dose measurement with Gafchromic™ films is very challenging mainly because of the non-uniformity response of flatbed scanners (used for films digitalization) and their own non-uniformity. The first proposal of this work is to develop bi-dimensional protocol for small beams and evaluate the associated uncertainty. The second proposal is to validate this protocol for the bi-dimensional measurements of treatment plans performed with the CyberKnife® system.First, the uniformity of an Epson V700 flatbed scanner and a batch of EBT3 Gafchromic™ films has been investigated. A “four films” dosimeter was designed to reduce the errors (statistic and systematic) due to their non-uniformity. Then, the “four films” dosimeter protocol in both a homogeneous (RW3 material) and heterogeneous (RW3, lung-like and bone-like materials) phantoms has been used to measure the bi-dimensional dose distributions of three simple CyberKnife® treatment plans. Two tumor locations (middle of the lung and near lung/bone interface) were considered for the heterogeneous phantom. These plans were achieved with the 10 mm fixed collimator and modeled with the PENELOPE Monte Carlo code in order to calculate accurate dose distributions. Finally, the “four films” bi-dimensional dose distributions were compared to the PENELOPE Monte Carlo simulations.Regarding the uncertainty associated to the bi-dimensional dose measurement protocol, the relative standard deviation σD on the dose was 1.2% in the range from 0.5 to 4.0 Gy. Regarding the protocol validation on CyberKnife® treatment plans, a very good agreement was found with all measurement points passing the {3% - 3 mm} Gamma Index criteria.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 89, June 2016, Pages 107–118
نویسندگان
, , , , , , , ,