کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1885279 1043402 2010 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and validation of a single sphere multi-detector neutron spectrometer based on LiF: Mg,Cu,P thermoluminescent dosemeters
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Design and validation of a single sphere multi-detector neutron spectrometer based on LiF: Mg,Cu,P thermoluminescent dosemeters
چکیده انگلیسی

This communication describes a new neutron spectrometer consisting of pairs of 7Li and 6Li based thermoluminescent dosemeters (MCP-6, MCP-7) located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix in order to obtain a nearly isotropic response for neutrons in the energy range up to 20 MeV. A partial validation of the calculated response matrix has been performed with the calibrated 241Am–Be neutron source at the INFN–LNF Laboratory, using the shadow cone technique.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 45, Issue 10, December 2010, Pages 1220–1223