کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1888582 1043714 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Post-irradiation storage and thermal stability of thermoluminescence glow peaks in LiF:Mg,Cu,Si
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Post-irradiation storage and thermal stability of thermoluminescence glow peaks in LiF:Mg,Cu,Si
چکیده انگلیسی

Newly developed LiF:Mg,Cu,Si was found to exhibit no significant fading on room temperature post-irradiation storage up to several months. In view of the wide variation in the reported data of fading of LiF:Mg,Cu,P exhibiting glow curve structure similar to that of LiF:Mg,Cu,Si, a study of the effect of post-irradiation storage and thermal treatments on the deconvoluted glow peaks of LiF:Mg,Cu,Si was undertaken. The decay of inseparable peak-3 by post-irradiation storage or thermal treatments did not indicate any rearrangement in the trap occupation that would affect the response of the main peak (peak-4). A post-irradiation treatment at 125 °C for 10 min was found to be the optimum to eliminate the lower temperature peaks.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Measurements - Volume 47, Issue 1, January 2012, Pages 96–99
نویسندگان
, , , , ,