کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2154127 1090218 2011 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Facile and rapid one-step radiosynthesis of [18F]BAY94-9172 with a new precursor
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی تحقیقات سرطان
پیش نمایش صفحه اول مقاله
Facile and rapid one-step radiosynthesis of [18F]BAY94-9172 with a new precursor
چکیده انگلیسی

Introduction[18F]BAY94-9172 (Florbetaben) (Compound 8) is a positron emission tomography (PET) tracer that is currently in Phase III study for in vivo mapping of fibrillar amyloid β as a pathological hallmark for Alzheimer's disease. This work reports new methods for the synthesis of [19F]BAY94-9172 and its two different precursors and radiosynthesis of [18F]BAY94-9172 with the two precursors by purification using Sep-Pak cartridge.MethodsThe reference standard [19F]BAY94-9172 and the new precursor (Compound 9) were obtained from the reactions of (E)-4-methylamino-4′-hydroxystilbene (Compound 1) with methanesulfonic acid 2-[2-(2-fluoro-ethoxy)-ethoxy]-ethyl ester (Compound 11) and methanesulfonic acid 2-[2-(2-methanesulfonyloxy-ethoxy)-ethoxy]-ethyl ester (Compound 13), respectively. The reported precursor (Compound 6) is an N-BOC-protected mesylate compound, which was obtained from Compound 9. The one-step radiosynthesis of [18F]BAY94-9172 was carried out in the modified PET-MF-2V-IT-1 synthesizer by [18F]fluorination of the new precursor (Compound 9) and purification with plus C18 Sep-Pak cartridges and was compared with two-step one-pot radiosynthesis using the reported precursor (Compound 6) and Sep-Pak cartridge purification.ResultsFor one-step radiosynthesis, the uncorrected radiochemical yield of [18F]BAY94-9172 was 23±3% (n=5, based on [18F]fluoride) within 30 min and the radiochemical purity was greater than 95%. For two-step one-pot radiosynthesis, the uncorrected radiochemical yield of [18F]BAY94-9172 was 17±2% in 45 min (n=4, based on [18F]fluoride) with the radiochemical purity being above 95% after the Sep-Pak cartridge purification.Conclusion[19F]BAY94-9172 and the two precursors were synthesized by a short synthetic route. Compared with HPLC purification, the use of Sep-Pak purification of [18F]BAY94-9172 reduced the total radiosynthesis time. The one-step radiosynthesis of [18F]BAY94-9172 is convenient and can easily be applied to the commercial PET tracer synthesizer for automated synthesis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Medicine and Biology - Volume 38, Issue 1, January 2011, Pages 121–127
نویسندگان
, , , , ,