کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
227885 464830 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design and production of Hg0 calibrator, Hg2+ calibrator, and Hg2+ to Hg0 converter for a continuous Hg emission monitor
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Design and production of Hg0 calibrator, Hg2+ calibrator, and Hg2+ to Hg0 converter for a continuous Hg emission monitor
چکیده انگلیسی

Hg calibration and conversion systems, which are integral parts of a continuous emission monitor for were designed, produced, and tested. First, both Hg0 and Hg2+ calibrators showed less than 10% difference between measured and theoretical values. Next, a Hg2+ to Hg0 thermal converter with a scrubber and heated gas lines showed a conversion efficiency higher than 95%. Finally, the laboratory-prepared Hg converter was tested at a full-scale medical waste incinerator. The Ontario Hydro Method was used for measurement and speciation of Hg. The results showed that the laboratory-prepared Hg converter was highly effective with highest conversion efficiency close to 94%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Industrial and Engineering Chemistry - Volume 19, Issue 5, 25 September 2013, Pages 1560–1565
نویسندگان
, , , , ,