کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
236510 | 465672 | 2014 | 5 صفحه PDF | دانلود رایگان |
• Powder flowability of cement raw meal is measured in a monoaxial shear tester.
• Temperatures up to 850 °C have been investigated.
• At temperatures above 550 °C, flowability is reduced.
• Belite formation and possibly calcination sinter the raw meal.
The flowability of cement raw meal is investigated at temperatures up to 850 °C in a specially designed monoaxial shear tester. Consolidation stresses of 0.94, 1.87 and 2.79 kPa are applied. The results show that the flowability is reduced as temperature is increased above 550 °C, indicated by increasing unconfined yield strength and reduced flowability factors. Deviation and reproducibility are acceptable for all temperatures except for 850 °C where belite formation and possibly calcination sinter the raw meal.
Powder flowability of raw meal is investigated at temperatures up to 850 °C in a monoaxial shear tester. Consolidation stresses of 0.94, 1.87 and 2.79 kPa are applied. The results show that the flowability is reduced as temperature is increased above 550 °CFigure optionsDownload as PowerPoint slide
Journal: Powder Technology - Volume 253, February 2014, Pages 686–690