کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
238340 465752 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Continuous reduction of toluene vapours from the contaminated gas stream in a fluidised bed photoreactor
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Continuous reduction of toluene vapours from the contaminated gas stream in a fluidised bed photoreactor
چکیده انگلیسی

Continuous reduction of toluene vapours in a gas fluidised bed photoreactor was studied using TiO2-coated activated carbon (AC/TiO2) particles as the fluidising media. The toluene vapour concentration before treatment was in the range between 200 and 1000 ppm and was relatively high compared to previous similar research works. The experimental results showed that the effective toluene reduction duration (according to the Standards of Permissible Exposure Limits of Toluene in Taiwan) was improved for approximately 130–137% using AC/TiO2 particles as the fluidising media compared to that using AC particles as the fluidising media in the fluidised bed photoreactor with the gas flow rate between 3 and 15 L/min. When the gas stream with the toluene vapour concentration 200 ppm, the relative humidity 30% and the flow rate 3 L/min was deducted in the fluidised bed photoreactor using AC/TiO2 particles as the fluidising media, the conditioned gas could pass the toluene permissible exposure limit in Taiwan for more than 11 h.

Continuous reduction of toluene vapours in a gas fluidised bed photoreactor was studied using TiO2-coated activated carbon (AC/TiO2) particles as the fluidising media. The toluene vapour concentration before treatment was in the range between 200 and 1000 ppm and was relatively high compared to previous similar research works. The effective toluene reduction duration was improved for approximately 130–137% using AC/TiO2 particles as the fluidising media compared to that using AC particles as the fluidising media in the fluidised bed photoreactor with the gas flow rate between 3 and 15 L/min. When the gas stream with the toluene vapour concentration 200 ppm, the relative humidity 30% and the flow rate 3 L/min was deducted in the fluidised bed photoreactor using AC/TiO2 particles as the fluidising media, the conditioned gas could pass the toluene permissible exposure limit in Taiwan for more than 11 h.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Powder Technology - Volume 195, Issue 1, 10 October 2009, Pages 50–56
نویسندگان
, , ,