کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
243091 501919 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring the performance of single and triple junction amorphous silicon modules in two building integrated photovoltaic (BIPV) installations
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Monitoring the performance of single and triple junction amorphous silicon modules in two building integrated photovoltaic (BIPV) installations
چکیده انگلیسی


• The first and the largest BIPV of Turkey were installed.
• Single and triple junction amorphous module performances in BIPV applications are analyzed.
• Total generated electricity of the BIPV system is measured as 103,702 kW h for 36 months of operation.
• Annual energy rating is calculated as 856 kW h/kWp for a non-optimally oriented plant.
• The PR of the system is found 0.74 and 0.81 for PV systems on towers and facade respectively.

Mugla is located in south west Turkey at 37°13′N latitude and 28°36′E longitude with yearly sum of horizontal global irradiation exceeding 1700 kW h per square meter. Mugla has a Mediterranean Climate which is characterized by long, hot and dry summers with cool and wet winters. Mugla Sıtkı Kocman University is the largest “PV Park” in Turkey consisting of 100 kWp installed Photovoltaic Power Systems (PVPSs) with different PV applications. The 40 kWp building integrated photovoltaic (BIPV) system which is the first and largest in Turkey was installed on the façade and the two towers of the “Staff Block of the Education Faculty’s Building” of Mugla Sıtkı Kocman University in February 2008. Triple junction amorphous silicon photovoltaic modules are used on the façade and single junction amorphous silicon PV modules are used on the East and West towers of the building. In this paper, the 40 kWp BIPV system in Mugla, Turkey is presented, and its performance is evaluated. Energy rating (kW h/kWp energy yield), efficiencies and performance ratios of both applications are also evaluated for 36 months of operation. Daily, monthly and seasonal variations in performance parameters of the BIPV system in relation to solar data and meteorological parameters and outdoor performance of two reference modules (representing the modules on façade and towers) in a summer and a winter day are also investigated.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 109, September 2013, Pages 154–162
نویسندگان
, ,