کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
243305 | 501927 | 2012 | 6 صفحه PDF | دانلود رایگان |
Effective removal of nitrogen oxides (NOx) from flue gas allows more fossil fuels to be produced and utilized with less negative impact on the environment. It would be more cost-effective, however, if nitric oxide (NO) is oxidized to soluble nitrate and nitrite and then removed from the air by existing desulfurization wet scrubbers. This paper compares the effectiveness of three different oxidants for this purpose, namely, ethylenediaminetetraacetic acid; iron (2+) (Fe(II)–EDTA), hexamminecobalt(II) chloride ([Co(NH3)6]Cl2), and hydrogen peroxide (H2O2). Experimental results using column reactors showed that [Co(NH3)6]Cl2 was more effective over the same period of time. The best initial NO removal efficiency of about 96.45% was measured at the inlet flow rate of 500 ml/min; the temperature of approximately 19 °C; the pH value of around 10.5; and the concentrations of [Co(NH3)6]Cl2 , NO and O2 of 0.06 mol/L, 500 ppm and 5.0%, respectively.
Journal: Applied Energy - Volume 93, May 2012, Pages 53–58