کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
244471 501951 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dimensionless lumped formulation for performance assessment of adsorbed natural gas storage
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Dimensionless lumped formulation for performance assessment of adsorbed natural gas storage
چکیده انگلیسی

Adsorbed natural gas (ANG) has been emerging as an attractive alternative to compressed natural gas or liquefied natural gas, on various circumstances. However, in spite of the advantages associated with ANG over other storage modes, there are some issues that need be properly addressed in order to ensure a viable employment of such alternative. One major problem is that the thermal effects associated with the sorption phenomena tend to diminish the storage capacity, thereby resulting in poorer performance. Hence, in order to design commercially viable storage vessels, the heat and mass transfer mechanisms that occur in these devices must be carefully understood and controlled. With the purpose of improving the understanding of mass and energy transport within ANG vessels, dimensionless groups associated with this problem have been developed in this study, resulting in an innovation to the ANG literature. Along with the dimensionless groups, a lumped-capacitance formulation has been also proposed. Although this type of formulation is limited compared to the multi-dimensional formulations present in the literature, its computational solution is remarkably faster. Numerical solution results using the proposed lumped formulation are compared with those of a previous study, suggesting that the simpler model can be applied to larger process times. The process of charging and discharging ANG vessels was then simulated employing the proposed formulation for different combinations of the developed dimensionless groups. In order to properly assess charge and discharge processes, a performance coefficient was employed. The results show that increasing the heat capacity ratio and dimensionless heat transfer coefficient tend to augment the performance coefficient, whereas an increase in the dimensionless heat of sorption worsens performance. The proposed normalization scheme is applicable to both multi-dimensional and spatially-lumped formulations, thereby facilitating the analysis of heat transfer enhancement in these storage vessels.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 87, Issue 5, May 2010, Pages 1572–1580
نویسندگان
, ,