کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
244618 501956 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Energy reduction schemes for multiple effect evaporator systems
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Energy reduction schemes for multiple effect evaporator systems
چکیده انگلیسی

In the present work different energy reduction schemes (ERSs), used to reduce the consumption of steam for a multiple effect evaporator (MEE) system, are developed. These ERSs are condensate-, feed- and product-flashing and vapor bleeding. Further, a new scheme is proposed where condensate of vapor chest of an effect is used to preheat the liquor, which is entering into that effect using a counter current heat exchanger. This work also presents a comparative study between existing ERSs and selects the best ERS amongst these based on steam consumption as well as number of units involved. Further, in the present paper a simple graphical approach named “modified temperature path (MTP)” is developed for the analysis of different feed flow sequences of a MEE system to screen best possible feed flow sequence. To study the effect of different ERSs on steam consumption and MTP analysis an example of septuple effect flat falling film evaporator (SEFFFE) system, employed for concentrating weak black liquor in an Indian Kraft Paper Mill, is considered. The results show that ERSs reduce the steam consumption up to 24.6%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 87, Issue 4, April 2010, Pages 1102–1111
نویسندگان
, ,