کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
249987 | 502646 | 2007 | 8 صفحه PDF | دانلود رایگان |

Maintenance of good indoor air quality for residences could be very challenging. Episodic event such as cooking emits a large amount of ultrafine and supermicron particles. A numerical model is used to simulate a 10-min cooking process in a real room, followed by a few more minutes to allow the decay and removal of particles. Particle dispersion and deposition in the kitchen and the living room are simulated by a new drift-flux model. Strong buoyancy flow is observed and particle concentration is significantly affected by the thermal plume. Results show that for supermicron particles strong non-uniformity of concentration is observed in the kitchen but the non-uniformity is less obvious in the living room. Exposure analysis must take into account the influence of the particle sizes.
Journal: Building and Environment - Volume 42, Issue 9, September 2007, Pages 3253–3260