کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
249993 | 502646 | 2007 | 11 صفحه PDF | دانلود رایگان |

Under the Building Codes of Hong Kong Special Administration Region, the provision of refuge floors has been an indispensable element in high-rise building design since 1996. Wind-induced cross natural ventilation is an important design criterion of a refuge floor since it helps to prevent any smoke entering to become persistent state remained (logging) on the refuge floor. This paper reports a study of refuge floor natural ventilation induced by wind flow around a high-rise building with a refuge floor arriving from different wind incidence angles. The study is based on CFD simulations which are validated by wind tunnel measurements. The refuge floor under investigation has a main services core at the centre and support walls flush with the building walls along two opposite sides. The results reveal that at all wind angles, wind is able to enter the refuge space from the windward side and escape from the leeward side. At some wind angles, wind is found to re-enter the refuge space from the leeward opening and accumulate behind the main services core. Based on the results, we suggest that stairs connecting to the refuge space should be located inside the side corridors formed by the internal and external side walls.
Journal: Building and Environment - Volume 42, Issue 9, September 2007, Pages 3322–3332