In Steel–Concrete–Steel (SCS) sandwich structure, mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel–concrete interface. In this paper, novel shear connectors such as J-hook and cable shear connectors are proposed and their performance to achieve composite strength of SCS sandwich structures is investigated. The use of these connectors together with ultra-lightweight cement composite core reduces the overall weight of SCS sandwich system making it suitable for the construction of marine and offshore structures. Static tests were carried out on SCS sandwich beams with J-hook, cable shear connectors and headed studs. Their ultimate strengths were reported and their respective failure modes were discussed. An analytical method to predict the ultimate strength of the Steel–Concrete–Steel sandwich beams with various types of shear connectors was developed and its accuracy was ascertained by comparing with the test results. Deign recommendations are made on minimum connector spacing to prevent shear cracking of concrete core and local buckling of face plates.
Journal: Composite Structures - Volume 94, Issue 12, December 2012, Pages 3500–3509