The main goal of this paper is to evaluate the possibility of application or replacement of radiators with low-temperature radiant panels. This paper shows the comparison results of operations of 4 space heating systems: the low-temperature radiant panel system without any additional thermal insulation of external walls (PH-WOI), the low-temperature radiant panel system with additional thermal insulation of external walls (PH-WI), the radiator system without any additional thermal insulation of external walls (the classical heating system) (RH-WOI), and the radiator system with additional thermal insulation of external walls (RH-WI). The operation of each system is simulated by software EnergyPlus. The investigation shows that the PH-WI gives the best results. The RH-WOI has the largest energy consumption, and the largest pollutant emission. However, the PH-WI requires the highest investment.
► We analysed radiator heating system and radiant wall heating system.
► Analysed building is a residential house.
► Wall heating with thermal insulation provides the lowest energy consumption.
► Wall heating with thermal insulation provides the lowest CO2 emission.
► Embodied energy of thermal insulation does not much affect the total energy.
Journal: Energy and Buildings - Volume 54, November 2012, Pages 496–502