Hygrothermal analysis of a stabilised rammed earth test building in the UK
چکیده انگلیسی

This paper describes the analysis of the hygrothermal behaviours of stabilised rammed earth (SRE) walls used in a building in the UK. The analysis was achieved by computer simulation using WUFI Plus v1.2 whole building hygrothermal analysis software. To validate the model, an unoccupied test room in an unheated SRE building was monitored for 10 months. The hygrothermal properties of the SRE material were measured in the laboratory. It is shown that the SRE walls significantly reduced the amplitude of relative humidity fluctuations in the room air and reduced the frequency of high humidity periods at the wall surface. By adapting the model to represent an occupied and conditioned space, it is demonstrated that SRE walls have the potential to reduce the energy demand for humidification/dehumidification plant.