کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
264743 504111 2010 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Energy performance assessment of double-skin façade with thermal mass
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Energy performance assessment of double-skin façade with thermal mass
چکیده انگلیسی

To mitigate the overheating problem in the warmer seasons, and thereby improve thermal performance and energy efficiency of the double-skin façade (DSF) system, this study introduced an innovative design approach involving the integration of passive thermal mass technique with the air channel of the conventional DSF. To assess the contribution of this integration to energy efficiency of the system, a numerical model was developed, capable of determining the thermal performance of the conventional DSF. The numerical model is composed of airflow and thermal models. This paper briefly describes the development of the models as well as the models’ verifications. Models were then used to carry out a series of parametric studies to investigate the effect of thermal mass on the energy performance of the integrated system.The simulation results revealed that mechanically ventilated DSF can save energy based on configuration from 21% to 26% in summer and from 41% to 59% in winter as compared to conventional DSFs without thermal mass. The results also showed the total saving for a naturally ventilated DSF is negligible year-round.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 42, Issue 9, September 2010, Pages 1499–1509
نویسندگان
, , ,