Night cooling with a Ventilated Internal Double Wall
چکیده انگلیسی

This study investigates the feasibility of a device to improve summer comfort in wood-frame houses using a Ventilated Internal Double Wall (VIDW). The idea is to increase the house's thermal inertia and to evacuate accumulated heat during the night with a mechanical ventilation system. The VIDW is a cooling wall. Numerous studies on night ventilation have been conducted, but the active ventilation inside the air gap of a double wall with high thermal inertia has not been studied. The first part of this study examines the impact of VIDWs on the thermal comfort in a timber-frame house. The VIDW is modeled in transient mode based on an electrical analogy with the assumption that the exchange coefficients are constant for a given air velocity. In addition, modeling a stationary CFD in forced convection of the VIDW air gap allowed us to study the cooling potential and the benefit of installing obstacles.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 42, Issue 3, March 2010, Pages 393–400