Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier
چکیده انگلیسی

On-site assessment of hygric and thermal performance of an interior thermal insulation system on the basis of hydrophilic mineral wool is presented in the paper. The system is applied during the summer period on a brick-built house from the end of 19th century. Hygrothermal testing is done during the time period of 4 years. The reconstructed building envelope exhibits very good hygrothermal performance. The thermal resistance increases approximately two times. Water condensation is never observed inside the envelope during the whole testing period. A comparison with the previous experiment in semi-scale conditions which was performed for similar insulation system constructed during the winter season shows that the precedence should be given to the application of the system in summer period as it is more considerate to the old masonry.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 41, Issue 1, January 2009, Pages 51–55