کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
265460 504160 2008 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Natural ventilation in the double skin facade with venetian blind
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Natural ventilation in the double skin facade with venetian blind
چکیده انگلیسی

As a new-style building, the thermal performance of double skin facade with the venetian blind cannot be predicted for the absence of suitable tool. In the paper, a detailed analysis of the thermal process in glass double facade with venetian blind was made. The governing equations were solved by comprising CFD, optical and heat balance model for multi-layer transparent system. It is shown that the more complex natural ventilation exists in the two air gaps divided by venetian blind, which cannot be reflected with the simplified model. Comparing the simulation results with the experiment data in the literature, a good agreement was achieved. Hence, it can be used as a reliable tool to analyze the ventilation in the double skin facade with a venetian blind.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 40, Issue 8, 2008, Pages 1498–1504