کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
265465 504160 2008 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Low-energy envelope design of residential building in hot summer and cold winter zone in China
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Low-energy envelope design of residential building in hot summer and cold winter zone in China
چکیده انگلیسی

With the development of the economy, the demand for energy in hot summer and cold winter zone in China is increasing very fast while the energy supply is going short. Air conditioning both for cooling and heating accounts for more than 50% of the total electricity used in the residential sector. This paper used eQUEST software to analyze envelope design on energy saving of air conditioner (AC) and the effects of energy saving strategies on AC electric consumption of different orientation rooms in hot summer and cold winter zone in China, which included exterior wall thermal insulation, solar radiation absorptance of exterior wall, area ratio of window to wall, categories of glazing and kinds of shading system, and two combined strategies. The results indicate that envelope shading and exterior wall thermal insulation are the best strategies to decrease the AC electric consumption which achieved a saving of 11.31 and 11.55%. The optimization of different strategies can decrease the annual electric consumption of AC by 25.92%, and cooling and heating electric consumption is decreased by 21.08 and 34.77%, respectively.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 40, Issue 8, 2008, Pages 1536–1546