A Method for Assessment of Blood Volume Parameters in Pregnant Sheep using Fluorescein-labelled Dextran
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شناسی تکاملی
پیش نمایش صفحه اول مقاله
A Method for Assessment of Blood Volume Parameters in Pregnant Sheep using Fluorescein-labelled Dextran
چکیده انگلیسی

The assessment of blood volume parameters in clinical and research settings has been limited by methods that involve radioactivity, complex assays or are unreliable. We aimed to design a method for measuring blood volume parameters that was non-radioactive, simple, cheap and reliable. We have used a commercially available fluorescein-labelled 250 kDa dextran, a large inert molecule, and have measured dilution of this through the intravascular space of pregnant ewes. From this estimation of plasma volume and measured hematocrit, we have calculated blood volume and red cell volume. The blood volume results are 6% lower than those obtained using radiolabelled red cells, but there is no significant difference in red cell volume between methods. The coefficient of variation for repeated measurements of plasma volume measurements is 3.8%. This is a simple, reliable, cheap and non-radioactive method for estimating blood volume parameters in pregnant sheep, and may prove useful in other settings.