کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
284966 509173 2013 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Block shear strength of coped beams with single-sided bolted connection
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Block shear strength of coped beams with single-sided bolted connection
چکیده انگلیسی


• Seven coped beam specimens with single-sided bolted connection were tested.
• Test parameters included the out-of-plane eccentricity and web block aspect ratio.
• The block shear capacity of the specimens was not affected by the eccentricity.
• Finite element analyses of the specimens were conducted.
• Various design codes were used to predict the capacity of the specimens.

Block shear is one of the major failure modes for coped steel I-beams. While focus of previous studies on the block shear capacity of coped steel I-beam was mainly given to the connections with double clip angles, single-sided connections, which induce out-of-plane loading eccentricity, have not been adequately considered. Ten full-scale coped steel I-beam tests were conducted to examine the effects of two main test parameters, namely, out-of-plane loading eccentricity and web block aspect ratio (ratio of shear area to tension area). It was found that nine test specimens failed with tension fracture along the bottom bolt row of the web, and the remaining one failed in a whole block tear-out manner. Twisting of the web near the cope was observed for specimens with single-sided connection. More importantly, the test results showed that the out-of-plane loading eccentricity due to the single-sided connection did not have a detrimental effect on the block shear capacity of the specimens. Moreover, increasing the connection rotational stiffness could increase the block shear capacity. These effects are further discussed via a finite element analysis and a preliminary parametric study. Finally, the test results are compared with four major design standards. It is found that the Canadian Standards CAN/CSA-S16-09, which gives a test-to-predicted ratio ranged from 0.93 to 1.17, provided relatively good predictions for the specimens with single bolt line layout, while the predictions by other codes are too conservative. For those specimens with double bolt line layout, the capacities are underestimated by all the considered standards.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Constructional Steel Research - Volume 86, July 2013, Pages 153–166
نویسندگان
, , , ,