کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
285355 509192 2011 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Fire resistance of concrete encased steel columns under 3- and 4-side standard heating
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Fire resistance of concrete encased steel columns under 3- and 4-side standard heating
چکیده انگلیسی

Results from seven fire resistance experiments on concrete encased steel (CES) columns under standard fire exposure conditions are presented. The test parameters include column size, 3- and 4-side fire exposure, load intensity and load eccentricity. Data from the tests is utilized to study the effect of the aforementioned parameters on thermal and structural response of concrete encased steel columns. Test results show that CES columns have higher fire resistance under 3-side heating than that under 4-side heating. Also, load ratio and load eccentricity have a noticeable influence on the fire resistance of CES columns. In addition, spalling of the concrete decreases the fire resistance of CES columns. A comparison of measured fire resistance of CES columns with those predicted using current code provisions indicate that the current provisions may not be conservative in some situations.

Research highlights
► Results from fire resistance experiments on seven CES columns are presented.
► Effect of column size, 3- and 4-side heating, load level and eccentricity are studied.
► Fire response of CES columns are traced till failure.
► Spalling, load level and eccentricity have a noticeable influence on fire resistance.
► Fire resistance code provisions for CES columns may not always be conservative.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Constructional Steel Research - Volume 67, Issue 3, March 2011, Pages 270–280
نویسندگان
, ,