Investigation on slenderness ratios of built-up compression members
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Investigation on slenderness ratios of built-up compression members
چکیده انگلیسی

This study provides a direct experimental verification of the AISC slenderness ratio formulas for built-up compressive members. The comparison on various code-specified slenderness ratios or provisions, which used in the AISC-ASD, AISC-LRFD, AS-4100, and CSA S16-01, are presented. The 0.75 rule, which states that the slenderness ratio of component element of built-up member should not exceed three-fourths times the governing slenderness ratio of built-up member, seems justified according to the tests. The governing slenderness ratio of built-up member could be either the modified or the unmodified one — as specified in the AISC Specifications. The test results indicate that the built-up members with component slenderness ratio of 0.75 to 1.0 times the governing slenderness ratio (modified or unmodified) could also furnish a quite encouraging design outcome. The use of separation ratio (α)(α) in built-up compression members results in the decrease of design strength when compared to one with no use of separation ratio.