کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
309258 513591 2013 21 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental study of load bearing cold-formed steel wall systems under fire conditions
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Experimental study of load bearing cold-formed steel wall systems under fire conditions
چکیده انگلیسی

Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.


► Light Gauge Steel Framing walls were tested under standard fire conditions.
► A new composite wall panel was proposed with an external insulation layer.
► Conventional cavity insulation led to inferior fire performance of walls.
► Externally insulated wall panels increased the fire resistance rating.
► Provided useful time–temperature and deflection profiles with failure times and modes of load bearing walls.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thin-Walled Structures - Volume 65, April 2013, Pages 72–92
نویسندگان
, , ,