کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
467650 698099 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Semi-automated and fully automated mammographic density measurement and breast cancer risk prediction
ترجمه فارسی عنوان
پیش بینی خطر ابتلا به سرطان پستان نیمه اتوماتیک و کاملا خودکار اندازه گیری تراکم ماموگرافی
کلمات کلیدی
تراکم ماموگرافی، ارزیابی تراکم اتوماتیک، تشخیص کامپیوتری، تجزیه و تحلیل تصویر، خطر ابتلا به سرطان پستان
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر علوم کامپیوتر (عمومی)
چکیده انگلیسی

The task of breast density quantification is becoming increasingly relevant due to its association with breast cancer risk. In this work, a semi-automated and a fully automated tools to assess breast density from full-field digitized mammograms are presented. The first tool is based on a supervised interactive thresholding procedure for segmenting dense from fatty tissue and is used with a twofold goal: for assessing mammographic density (MD) in a more objective and accurate way than via visual-based methods and for labeling the mammograms that are later employed to train the fully automated tool. Although most automated methods rely on supervised approaches based on a global labeling of the mammogram, the proposed method relies on pixel-level labeling, allowing better tissue classification and density measurement on a continuous scale. The fully automated method presented combines a classification scheme based on local features and thresholding operations that improve the performance of the classifier. A dataset of 655 mammograms was used to test the concordance of both approaches in measuring MD. Three expert radiologists measured MD in each of the mammograms using the semi-automated tool (DM-Scan). It was then measured by the fully automated system and the correlation between both methods was computed. The relation between MD and breast cancer was then analyzed using a case–control dataset consisting of 230 mammograms. The Intraclass Correlation Coefficient (ICC) was used to compute reliability among raters and between techniques. The results obtained showed an average ICC = 0.922 among raters when using the semi-automated tool, whilst the average correlation between the semi-automated and automated measures was ICC = 0.838. In the case–control study, the results obtained showed Odds Ratios (OR) of 1.38 and 1.50 per 10% increase in MD when using the semi-automated and fully automated approaches respectively. It can therefore be concluded that the automated and semi-automated MD assessments present a good correlation. Both the methods also found an association between MD and breast cancer risk, which warrants the proposed tools for breast cancer risk prediction and clinical decision making. A full version of the DM-Scan is freely available.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computer Methods and Programs in Biomedicine - Volume 116, Issue 2, September 2014, Pages 105–115
نویسندگان
, , , , , , , , , ,