کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
468271 698209 2015 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluating geodesic active contours in microcalcifications segmentation on mammograms
ترجمه فارسی عنوان
ارزیابی خطوط فعال ژئودزیک در تقسیم بندی microcalcifications بر روی ماموگرام
کلمات کلیدی
سرطان پستان؛ Microcalcification؛ تقسیم بندی؛ خطوط فعال ژئودزیک؛ ماموگرافی؛ دانش رادیولوژیست
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر علوم کامپیوتر (عمومی)
چکیده انگلیسی


• Microcalcification segmentation method based on geodesic active contours.
• Method incorporates radiologists’ knowledge in its final stage.
• 86.9% of microcalcifications were adequately segmented.
• Performance satisfactory for microcalcifications larger than 460 μm.
• Modest performance when segmenting microcalcifications smaller than 460 μm.

Breast cancer is the most commonly occurring type of cancer among women, and it is the major cause of female cancer-related deaths worldwide. Its incidence is increasing in developed as well as developing countries. Efficient strategies to reduce the high death rates due to breast cancer include early detection and tumor removal in the initial stages of the disease. Clinical and mammographic examinations are considered the best methods for detecting the early signs of breast cancer; however, these techniques are highly dependent on breast characteristics, equipment quality, and physician experience. Computer-aided diagnosis (CADx) systems have been developed to improve the accuracy of mammographic diagnosis; usually such systems may involve three steps: (i) segmentation; (ii) parameter extraction and selection of the segmented lesions and (iii) lesions classification. Literature considers the first step as the most important of them, as it has a direct impact on the lesions characteristics that will be used in the further steps. In this study, the original contribution is a microcalcification segmentation method based on the geodesic active contours (GAC) technique associated with anisotropic texture filtering as well as the radiologists’ knowledge. Radiologists actively participate on the final step of the method, selecting the final segmentation that allows elaborating an adequate diagnosis hypothesis with the segmented microcalcifications presented in a region of interest (ROI). The proposed method was assessed by employing 1000 ROIs extracted from images of the Digital Database for Screening Mammography (DDSM). For the selected ROIs, the rate of adequately segmented microcalcifications to establish a diagnosis hypothesis was at least 86.9%, according to the radiologists. The quantitative test, based on the area overlap measure (AOM), yielded a mean of 0.52 ± 0.20 for the segmented images, when all 2136 segmented microcalcifications were considered. Moreover, a statistical difference was observed between the AOM values for large and small microcalcifications. The proposed method had better or similar performance as compared to literature for microcalcifications with maximum diameters larger than 460 μm. For smaller microcalcifications the performance was limited.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computer Methods and Programs in Biomedicine - Volume 122, Issue 3, December 2015, Pages 304–315
نویسندگان
, , , , , ,