A low-cost real time virtual system for postural stability assessment at home
ترجمه فارسی عنوان
یک سیستم مجازی ارزان قیمت واقعی برای ارزیابی ثبات در خانه
کلمات کلیدی
ارزیابی پایداری مجازی، پلت فرم نیروی ایستلیومتری، نمایندگی مدل بدن، الگوریتم های شناخت و ردیابی، استفاده از وسایل خانگی خانگی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر علوم کامپیوتر (عمومی)
چکیده انگلیسی


• Equilibrium conditions control is very important in the elderly and in many pathologies.
• Equilibrium control is commonly evaluated by using a stabilometric platform.
• A low-cost virtual stabilometric platform is presented.
• Results demonstrate that the virtual stabilometric platform is equivalent to a physical one.

Background and objectiveThe degeneration of the balance control system in the elderly and in many pathologies requires measuring the equilibrium conditions very often. In clinical practice, equilibrium control is commonly evaluated by using a force platform (stabilometric platform) in a clinical environment.In this paper, we demonstrate how a simple movement analysis system, based on a 3D video camera and a 3D real time model reconstruction of the human body, can be used to collect information usually recorded by a physical stabilometric platform.MethodsThe algorithm used to reconstruct the human body model as a set of spheres is described and discussed. Moreover, experimental measurements and comparisons with data collected by a physical stabilometric platform are also reported. The measurements were collected on a set of 6 healthy subjects to whom a change in equilibrium condition was stimulated by performing an equilibrium task.ResultsThe experimental results showed that more than 95% of data collected by the proposed method were not significantly different from those collected by the classic platform, thus confirming the usefulness of the proposed system.ConclusionsThe proposed virtual balance assessment system can be implemented at low cost (about 500$) and, for this reason, can be considered a home use medical device. On the contrary, astabilometric platform has a cost of about 10,000$ and requires periodical calibration. The proposed system does not require periodical calibration, as is necessary for stabilometric force platforms, and it is easy to use. In future, the proposed system with little integration can be used, besides being an emulator of a stabilometric platform, also to recognize and track, in real time, head, legs, arms and trunk, that is to collect information actually obtained by sophisticated optoelectronic systems.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computer Methods and Programs in Biomedicine - Volume 117, Issue 2, November 2014, Pages 322–333
نویسندگان
, , , , , , ,