کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4919522 1428957 2016 52 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A hygrothermal dynamic zone model for building energy simulation
ترجمه فارسی عنوان
یک مدل منطقه پویای هیروترمال برای شبیه سازی انرژی ساختمان
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
The IEA agency in its annex 41 deals with the modelling of heat, air and moisture (HAM) transfer in whole buildings. In its words, coupling among these phenomena is crucial for future energy optimization of buildings. Computational fluid dynamics (CFD) is difficult and costly to use for everyday practice. Instead, popular building energy simulation software tools (BES) use simplified models popularly known as multi-zone models. Historically the thermal methods were developed separately from the multi-zone airflows and with different purposes. In well-known multi-zone flow software-tools like CONTAM [1] or COMIS [2], the airflow is decoupled from the thermal problem. BES try to gather those separated efforts and couple both heat and the airflow phenomena using different strategies [3]. All this separated development and the increase in computation capacity, has led to a point where improvements are needed [3]. After a critical review of recent hygrothermal zone models, we present a proposal of a simplified zone model for the air-water mixture dynamics which can be used in BES. The resulting dynamical state variables are the zone dry temperature, absolute humidity, total pressure and dry air mass content. This means that, in contrast with other literature models, we employ three intensive and one extensive variable respectively. Moreover, the reference height level inside the zone cannot be chosen arbitrarily. The dynamic is obtained by using zone energy balance, balances of dry air and water mass content and the Equation of State for the wet air mixture. The zone can store dry air and water, therefore their density can change with time inside the volume. Inside the zone a hydrostatic pressure field is assumed with no kinetic energy storage. The resulting model is a made up of three non-linear ordinary differential equations and one algebraic equation. The model is automatically capable of dealing with wet air saturation conditions by using a special control signal αcontrol.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 133, 1 December 2016, Pages 389-402
نویسندگان
, , ,