کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
492353 721259 2011 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Energy performance and degradation over 20 years performance of BP c-Si PV modules
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر علوم کامپیوتر (عمومی)
پیش نمایش صفحه اول مقاله
Energy performance and degradation over 20 years performance of BP c-Si PV modules
چکیده انگلیسی

The energy performance and degradation of 3 BP PV modules, type BP 1233, operating for a period of just more than 20 years are studied and compared to the nominal power output data. The 3 PV modules power the outdoor lighting of the Solar Campus and perform smoothly for all this period, without any special treatment or maintenance, although they were physically weathered on a continuous basis. Life cycle power degradation was estimated from a series of i, V experiments carried out under field conditions. The experimental analysis led to the determination of the present peak power, at STC, the series and shunt resistances, Rs and Rsh, respectively, and the fill factor, FF. Causes of degradation and especially of its extent were attributed to discolouring, junctions’ damage, humidity ingress in the box, encapsulant delamination, hot spots, etc., as realized by in situ inspections.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Simulation Modelling Practice and Theory - Volume 19, Issue 4, April 2011, Pages 1201–1211
نویسندگان
, ,