کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4928520 1432072 2017 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental and numerical analysis on the slope change joint of a quartet-steel-tube-column transmission tower
ترجمه فارسی عنوان
تجزیه و تحلیل تجربی و عددی بر روی شیب تغییر مفصل یک برج انتقال دهنده فولاد-لوله-ستون
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
چکیده انگلیسی
In this paper, a new type of multi-planar slope change joint (abbreviation SCJ) in a new type of long span transmission tower is presented. Difference between the new tower and regular ones lies in the tower leg. In the new tower, each leg is a built-up column constituted with four steel tubes. The SCJ is a complicated multi-planar connection in the tower. Three-dimensional loading of the joint was achieved in the experiment. Detailed configuration of the SCJ and the experimental system were introduced. Finite element models of the SCJ were established and validated against experimental results. Experimental and numerical analysis results, under different cases, indicated that the joint zone was within the elastic bearing capacity. Buckling failures appeared in the upper or lower tubes. Then parametric studies were carried out to study different factors that may have influence on the ultimate load. Axial load distribution among the four lower tubes in the joint was also analysed. Finally, some joint design recommendations were proposed.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thin-Walled Structures - Volume 119, October 2017, Pages 572-585
نویسندگان
, , , , ,