A minimally interactive and reproducible method for abdominal aortic aneurysm quantification in 3D ultrasound and computed tomography with implicit template deformations
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
پیش نمایش صفحه اول مقاله
A minimally interactive and reproducible method for abdominal aortic aneurysm quantification in 3D ultrasound and computed tomography with implicit template deformations
چکیده انگلیسی
The maximum diameter of abdominal aortic aneurysm (AAA) is a key quantification parameter for disease assessment. Although it is routinely measured on 2D-ultrasound images, using a volumetric approach is expected to improve measurement reproducibility. In this work, 3D-ultrasound or computed tomography imaging of patients with AAA was combined with a minimally interactive 3D segmentation based on implicit template deformation. Segmentation usability and reproducibility were evaluated on 81 patients, showing a mean measurement time of [2;8] min per case, and Dice coefficients of 0.87 ± 0.12 for 3D-US and 0.81 ± 0.08 for CT. Quantification parameters included a diameter measurement from 3D-US and CT volumes with respective confidence intervals of 0.51 [−2.5;3.52] mm and 1.00 [−1.68;3.67] mm. Additional volume measurements showed confidence intervals of 0.91 [−4.17;5.99] ml for 3D-US and 4.10 [−4.11;12.30] ml for CT.