کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4977236 1451849 2017 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A generalised multiple-mass based method for the determination of the live mass of a force transducer
ترجمه فارسی عنوان
یک روش مبتنی بر چندجمله عمومی برای تعیین توده زنده یک مبدل نیروی
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر پردازش سیگنال
چکیده انگلیسی


- A novel method is proposed to measure the live mass of piezo force transducers.
- Accurate method by continuous self-calibration.
- Relevant in Modal Analysis applications where the live mass is needed.
- In theory, it can use any number of calibration masses.
- Method is demonstrated through both numerical and experimental examples.

Many applications in Experimental Modal Analysis (EMA) require that the sensors' masses are known. This is because the added mass from sensors will affect the structural mode shapes, and in particular its natural frequencies. EMA requires the measurement of the exciting forces at given coordinates, which is often made using piezoelectric force transducers. In such a case, the live mass of the force transducer, i.e. the mass as 'seen' by the structure in perpendicular directions must be measured somehow, so that compensation methods like mass cancelation can be performed. This however presents a problem on how to obtain an accurate measurement for the live mass. If the system is perfectly calibrated, then a reasonably accurate estimate can be made using a straightforward method available in most classical textbooks based on Newton's second law. However, this is often not the case (for example when the transducer's sensitivity changed over time, when it is unknown or when the connection influences the transmission of the force). In a self-calibrating iterative method, both the live mass and calibration factor are determined, but this paper shows that the problem may be ill-conditioned, producing misleading results if certain conditions are not met. Therefore, a more robust method is presented and discussed in this paper, reducing the ill-conditioning problems and the need to know the calibration factors beforehand. The three methods will be compared and discussed through numerical and experimental examples, showing that classical EMA still is a field of research that deserves the attention from scientists and engineers.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Mechanical Systems and Signal Processing - Volume 83, 15 January 2017, Pages 506-521
نویسندگان
, , , ,