کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4995090 1458490 2017 23 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental study on steam chugging phenomenon in a vertical sparger
ترجمه فارسی عنوان
مطالعه تجربی بر روی پدیده شل شدن بخار در یک اسپریگر عمودی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
چکیده انگلیسی
Unstable direct contact condensation called ``Chugging'' that occurs in certain conditions in the pressure suppression pool of Primary Containment Vessel of Boiling Water Reactors (BWRs) was studied experimentally. The mechanisms of every phase of the chugging was described, and experimental results useful for the development and validation of more accurate CFD models were provided. The experiment was conducted with a transparent pool and a transparent polycarbonate pipe or a stainless steel pipe with inner diameter of 27 mm under the conditions of the steam mass flux of 5.5-19.5 kg/m2s and the pool temperature of 19-46.5 °C. Pressure pulses were measured and synchronized with a high speed video camera for images acquisition. It was identified that the bubble implosion occurred while the pressure in the bubble quickly decreased. This condition might establish instability in the interfacial area which grew abruptly causing the implosion. Moreover the transparent apparatus allowed to interpret and relate internal condensations, generating pressure spikes of around 1.2 MPa because of the condensation-induced water hammer. Finally, the chugging condensation regime map was created from the experimental data.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Multiphase Flow - Volume 88, January 2017, Pages 87-98