کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5007941 1461706 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Single-camera stereo-digital image correlation with a four-mirror adapter: optimized design and validation
ترجمه فارسی عنوان
همبستگی تصویر استریو دیجیتال با یک آداپتور چهار آینه: طراحی بهینه و اعتبار سنجی
کلمات کلیدی
همبستگی تصویر دیجیتال استریو، اندازه گیری تغییر شکل آداپتور چهار آینه، تصویربرداری فعال
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی برق و الکترونیک
چکیده انگلیسی


- An optimized single-camera stereo-DIC system using a four-mirror adapter is established.
- The single-camera stereo-DIC system presents strong robustness against ambient light variations.
- The accuracy of the established system is verified by shape and 3D displacement measurements.
- It has great potential in determining transient deformation in non-laboratory or high-temperature environments.

A low-cost, easy-to-implement but practical single-camera stereo-digital image correlation (DIC) system using a four-mirror adapter is established for accurate shape and three-dimensional (3D) deformation measurements. The mirrors assisted pseudo-stereo imaging system can convert a single camera into two virtual cameras, which view a specimen from different angles and record the surface images of the test object onto two halves of the camera sensor. To enable deformation measurement in non-laboratory conditions or extreme high temperature environments, an active imaging optical design, combining an actively illuminated monochromatic source with a coupled band-pass optical filter, is compactly integrated to the pseudo-stereo DIC system. The optical design, basic principles and implementation procedures of the established system for 3D profile and deformation measurements are described in detail. The effectiveness and accuracy of the established system are verified by measuring the profile of a regular cylinder surface and displacements of a translated planar plate. As an application example, the established system is used to determine the tensile strains and Poisson׳s ratio of a composite solid propellant specimen during stress relaxation test. Since the established single-camera stereo-DIC system only needs a single camera and presents strong robustness against variations in ambient light or the thermal radiation of a hot object, it demonstrates great potential in determining transient deformation in non-laboratory or high-temperature environments with the aid of a single high-speed camera.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Optics and Lasers in Engineering - Volume 87, December 2016, Pages 120-128
نویسندگان
, ,