کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5009008 1462038 2017 40 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preparation of a porous Au electrode with a sacrificed Prussian blue analogue template for anodic stripping voltammetric analysis of trace arsenic(III)
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Preparation of a porous Au electrode with a sacrificed Prussian blue analogue template for anodic stripping voltammetric analysis of trace arsenic(III)
چکیده انگلیسی
A porous Au modified glassy carbon electrode (Autemp/GCE) is prepared by co-electrodeposition of Au and Au-based Prussian blue (PB) analogue template in an aqueous bath containing HAuCl4 and PB-precursors, followed by removal of the PB analogue template by alkali and then acidic treatments. The Autemp/GCE has large surface area (roughness factor = 64.6) and is employed to determine As(III) based on anodic stripping linear sweep voltammetry (ASLSV) in a dual-signal mode. Under optimal conditions, the ASLSV peak currents for oxidation of As(0) to As(III) and of As(III) to As(V) are linear with concentration of As(III) from 0.025 to 10 μM with a sensitivity of 1.13 mA μM−1 and a limit of detection (LOD) of 6.6 nM (0.49 μg L−1) (S/N = 3), and from 0.025 to 3.0 μM with a sensitivity of 0.88 mA μM−1 and a LOD of 8.5 nM (0.63 μg L−1) (S/N = 3), respectively. Determination of As(III) in real water samples on the Autemp/GCE yields satisfactory results.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 253, December 2017, Pages 603-611
نویسندگان
, , , , , , ,