کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5009162 1462043 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Selective colorimetric/visual detection of Al3+ in ground water using ascorbic acid capped gold nanoparticles
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Selective colorimetric/visual detection of Al3+ in ground water using ascorbic acid capped gold nanoparticles
چکیده انگلیسی


- The colorimetric/visual method for the selective detection of Al3+ is developed.
- The AA@ AuNPs has been used for the sensitive detection of Al3+ in ground water.
- RIEX process has been used to improve sensitivity of the method in ground water.
- The LOD of developed method was found to be 12.5 ppb in ground water.
- The methods can be useful for on-field screening of water samples.

A method for the selective and sensitive detection of aluminium (Al3+) in aqueous systems has been developed. The detection is achieved by the selective aggregation of ascorbic acid capped gold nanoparticles (AA-AuNPs) in the presence of aluminium which is observed by the change in colour of the colloidal solution from bright red to purple. The change in characteristic absorption peak can also be noticed spectrophotometrically; absorption of AA-AuNPs (λmax-520 nm) decreased and a second peak at 652 nm appeared after the addition of aluminium. The ratio of A652/A520 can be used to quantify the concentration of aluminium in water. The method gave a linear response from 20 ppb − 100 ppb (R2 = 0.996) of Al3+ in drinking water with a detection limit of 6.5 ppb. The proposed method did not suffer any interference from concomitant transition metal ions like: Mn2+, Ni2+, Zn2+, Sn2+, Li+, Co2+, Hg2+, Fe3+, and Pb2+ up to a concentration of 5 ppm and anions (Cl−, F−, SO42−, NO3−, PO43−) up to a concentration of 250 ppm. However, a concentration of Ca2+ (≥15 ppm) was found to interfere with the detection of Al3+ in ground water. The interference was eliminated by passing the water through an anion exchange resin converted into oxalate form for the removal of the interferant as calcium oxalate precipitate in the resin phase. After this pre-treatment the linearity range in ground water was found to be 100-350 ppb with R2 = 0.996 and LOD − 12.5 ppb. The simplicity and rapidity of the developed method shows great potential in favour of its application for screening of drinking water samples to check its safety with respect to aluminium toxicity.

76

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 248, September 2017, Pages 124-132
نویسندگان
, , ,