کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
505156 864477 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Approach for streamlining measurement of complex physiological phenotypes of upper airway collapsibility
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
پیش نمایش صفحه اول مقاله
Approach for streamlining measurement of complex physiological phenotypes of upper airway collapsibility
چکیده انگلیسی

The critical closing pressure (PCRIT), a quantitative assessment of upper airway collapsibility, is derived from pressure flow relationship during sleep. The analytic generation of the pressure flow relationships are non-standardized due to various regression models (linear, spline, median), breath characteristics (flow limited, non-flow limited) or known covariates (sleep stage, body position). We propose a GUI based PCRIT Analysis Software (PAS) to streamline PCRIT analysis and validate its reliability and accuracy compared to current analysis procedures.MethodsSeventeen subjects underwent a physiology sleep study in which the PCRIT was determined during NREM sleep. Data analysis was performed independently using three paradigms: (1) PAS (Igor Pro; median regression), (2) non-graphic statistics application (SAS; spline regression), and (3) manual spreadsheet calculations (Excel; linear regression). The reliability and accuracy of the PAS was examined through the agreement between each approach using Bland–Altman plots of the mean difference and within-individual variation using intra-class correlation (ICC).ResultsThere was no difference in the group mean values for PCRIT using the PAS (−1.7±0.7 cm H2O) compared to spline regression (−1.6±0.7 cm H2O; p=0.69) or linear regression (−2.1±0.7 cm H2O; p=0.92). The Bland–Altman analysis did not demonstrate a systematic bias between the PAS and either approach. There was a mean difference of 0.39±0.2 cm H2O between the PAS and linear regression approaches, with upper and lower limits of agreement of 1.81 and −1.02 cm H2O, respectively. The PAS and spline analyses demonstrated an even smaller mean difference of −0.10±0.1 cm H2O, with upper and lower limits of 0.90 and −1.08 cm H2O, respectively.ConclusionPAS preserves the reliability and accuracy of the original PCRIT analysis methods while vastly improving their efficiency through graphic user interface and automation of analytic processes. Providing a standardized platform for physiologic data processing offers the ability to implement quality assurance and control procedures for multicenter studies as well as cost saving by improving the efficiency of complex repetitive tasks.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computers in Biology and Medicine - Volume 43, Issue 5, 1 June 2013, Pages 600–606
نویسندگان
, , , , , , , , , ,